Dec 03, 2018 Leave a message

Second generation pumping technology of concrete conveyor pump: full liquid control commutative technology The first generation of pumping technology: electronically controlled commutative technology, PLC control solenoid valve commutative to achieve pumping, s tube distribution alternating shift. Machine assembly is simple, low production costs, but complex electrical control, failure rate and maintenance costs are extremely high, easy to delay the progress of the project is the biggest drawback.


1


Second generation pumping technology: Hydraulic commutative technology, completely rely on the main cylinder, the distribution of small cylinder hydraulic signal changes to achieve action change.

1, concrete pumping, s-tube distribution without PLC electrical components to participate, lower failure rate, more reliable control, product life is greatly improved.

2, full liquid control technology pump, no constant pressure pump, no plc in the control box, no nitrogen gas storage tank, water tank is not close to the switch, simple structure, maintenance costs greatly reduced.

1) The concrete pump should be placed on a solid flat ground, put down the leg, the fuselage will be placed smoothly.

2) before the operation should be checked to confirm the normal electrical equipment and instrumentation, all parts of the switch button, handle are in the correct position, mechanical part of the fastening point is firm, reliable, chain and belt tightness in line with the requirements, transmission parts operating normally. 

3) Concrete conveyor fittings should be sealed tightly, pipe card should be firmly connected.

Vertical pipe should be not less than 10m with the anti-stop valve horizontal pipe, it is strictly forbidden to connect the vertical pipe directly in the concrete pump output and outlet. 

4) When the blockage pipe is cleared, the surrounding personnel should be evacuated. Remove the pipe before cleaning should take the reverse pumping method to remove the pressure of the conveyor pipe.

It is strictly forbidden to control the mouth to the person when disassembling. 

5) The Hopper Grille and other safety devices shall not be removed during operation.

Do not climb and ride the pressure conveyor pipe, do not put the hand into the valve body to work, strictly prohibit the removal of the pipe when pumping. 

6) When cleaning the pipe, the operator should leave the pipe outlet and bend pipe joint.

If the pipe is cleaned with compressed air, no one or equipment shall be in the outlet of the pipe at the exit of 10m. 

7) After the operation, the hydraulic system will be unloaded, all the control switch back to the original position.